Datasheet
SENSOR
MICRO
CONTROLLER
SN65HVD101
V
CC
VCC_ IN
VCC_ SET
TX
EN
RX
PWR_OK
CUR_OK
WAKE
LIM ADJ
L+
CQ
L–
GND
IOLINK
MASTER
EVM Setup and Precautions
www.ti.com
JMP1 sets the current limit. Placing a shunt across 20K (pins 1-2) on JMP1 limits the current at the CQ
pin to 100 mA. Placing a shunt across GND (pins 3-4) on JMP1 limits the current to 400 mA. When
working with the SN65HVDHVD102 EVM, leave the shunt off and provide the 3.3-V or 5-V supply to the
VCC_IN terminal.
Microcontroller / IO-LINK Interface Signals
From the microcontroller, connect the EN (enable) signal to the EN post on JMP5, the microcontroller TX
signal to the EVM TX post on JMP4, the RX signal to the RX post on JMP3. Connect the master’s WAKE
signal to the WAKE post on JMP9, and the master CUR_OK signal to the CURR_OK post on JMP9. An
example is shown below in Figure 3.
Figure 3. IO-Link Application Example
3.2 EVM Jumper Settings
Table 1. EVM Jumper Settings
Jumper Description Setting Result
JMP1 CQ current limit adjust OPEN NA
20K – GND 100mA (Default)
POT-GND 400mA
JMP2 Power Supply Selection OPEN 5V Supply
VCC_SET – GND 3.3V Supply (Default)
VCC_SET – VCC_IN 5V Supply (internal pull-up on VCC_SET)
JMP3 RX Input OPEN RX signal to microcontroller
JMP4 TX Input OPEN TX signal to microcontroller
JMP5 Driver Enable/Disable VCC_IN – EN Driver is enabled
EN – GND Driver is disabled
JMP8 HVD101 - Voltage Sense VCC_IN – VCC_OUT Voltage Sense Feedback for the HVD101 internal voltage
Feedback regulator
HVD102 - Input Voltage OPEN VCC_IN = Supplied Vcc
Supply
JMP9 Microcontroller interface Contact pins for interfacing with a microcontroller
4
SN65HVD101 and SN65HVD102 EVM User's Guide SLLU178–February 2013
Submit Documentation Feedback
Copyright © 2013, Texas Instruments Incorporated