Datasheet

SM72480
www.ti.com
SNIS156C NOVEMBER 2010REVISED APRIL 2013
Accuracy Characteristics V
TEMP
Analog Temperature Sensor Output Accuracy
The limits do not include DC load regulation. The stated accuracy limits are with reference to the values in the SM72480
Conversion Table.
Units
Parameter Conditions Limits
(1)
(Limit)
T
A
= 20°C to 40°C V
DD
= 2.3 to 5.5 V ±1.8
T
A
= 0°C to 70°C V
DD
= 2.5 to 5.5 V ±2.0
T
A
= 0°C to 90°C V
DD
= 2.5 to 5.5 V ±2.1
V
TEMP
Temperature Trip Point °C
Accuracy
(2)
125°C or 120°C (max)
(2)
T
A
= 0°C to 120°C V
DD
= 2.5 to 5.5 V ±2.2
T
A
= 0°C to 150°C V
DD
= 2.5 to 5.5 V ±2.3
T
A
= –50°C to 0°C V
DD
= 3.0 to 5.5 V ±1.7
T
A
= 20°C to 40°C V
DD
= 1.8 to 5.5 V ±1.8
T
A
= 0°C to 70°C V
DD
= 1.9 to 5.5 V ±2.0
T
A
= 0°C to 90°C V
DD
= 1.9 to 5.5 V ±2.1
V
TEMP
Temperature Trip Point
°C (max)
Accuracy 105°C
T
A
= 0°C to 120°C V
DD
= 1.9 to 5.5 V ±2.2
T
A
= 0°C to 150°C V
DD
= 1.9 to 5.5 V ±2.3
T
A
= 50°C to 0°C V
DD
= 2.3 to 5.5 V ±1.7
(1) Limits are ensured to AOQL (Average Outgoing Quality Level).
(2) Accuracy is defined as the error between the measured and reference output voltages, tabulated in the Conversion Table at the
specified conditions of supply gain setting, voltage, and temperature (expressed in °C). Accuracy limits include line regulation within the
specified conditions. Accuracy limits do not include load regulation; they assume no DC load.
Electrical Characteristics
Unless otherwise noted, these specifications apply for +V
DD
= +1.6V to +5.5V. Boldface limits apply for T
A
= T
J
= T
MIN
to
T
MAX
; all other limits T
A
= T
J
= 25°C.
Units
Symbol Parameter Conditions Typical
(1)
Limits
(2)
(Limit)
GENERAL SPECIFICATIONS
I
S
Quiescent Power Supply
8 16 μA (max)
Current
5.5 °C (max)
Hysteresis 5
4.5 °C (Min)
OVERTEMP DIGITAL OUTPUT ACTIVE HIGH, PUSH-PULL
V
DD
1.6V Source 340 μA
V
DD
2.0V Source 498 μA V
DD
0.2V V (min)
V
DD
3.3V Source 780 μA
V
OH
Logic "1" Output Voltage
V
DD
1.6V Source 600 μA
V
DD
2.0V Source 980 μA V
DD
0.45V V (min)
V
DD
3.3V Source 1.6 mA
BOTH OVERTEMP and OVERTEMP DIGITAL OUTPUTS
V
DD
1.6V Sink 385 μA
V
DD
2.0V Sink 500 μA 0.2
V
DD
3.3V Sink 730 μA
V
OL
Logic "0" Output Voltage V (max)
V
DD
1.6V Sink 690 μA
V
DD
2.0V Sink 1.05 mA 0.45
V
DD
3.3V Sink 1.62 mA
(1) Typicals are at T
J
= T
A
= 25°C and represent most likely parametric norm.
(2) Limits are ensured to AOQL (Average Outgoing Quality Level).
Copyright © 2010–2013, Texas Instruments Incorporated Submit Documentation Feedback 5
Product Folder Links: SM72480