Datasheet
SD356EVK User Manual 8 of 11
Rev 1.0 © 2008, National Semiconductor Corp.
To generate the example output eye diagram shown, the PC and the spectrum analyzer are not required.
These items are used for other elements of the test procedure.
Table 2. Test Equipment and Material Required
Suggested Equipment
Description
Manufacturer Equipment Name Model
Number
Bit Error Rate Test Set with the following:
3 Gb/s Serial Data Capability
Jitter Injection Capability
Eye Diagram and Jitter
Measurement Capability
SyntheSys
Research
Agilent
Technologies
BERTScope
J-Bert
12500B
N4903A
DC Power Supply
3.3 V @ 0.5 A
Hewlett-Packard DC Power Supply E3610A
Spectrum Analyzer with minimum 3 GHz
bandwidth
Hewlett-Packard Portable Spectrum
Analyzer
8593E
Six (6) each UTIFlex coaxial cables
SMA connectors
36 inch length
Micro-Coax Inc. UTIFlex UFB205A-
0-0360-
000000