Datasheet
SCANSTA101
SNLS057J –MAY 2002–REVISED APRIL 2013
www.ti.com
Table 6. MACRO STRUCTURE
Bit(s) Function
0x1F Compare
0x1E Use Mask / Compare full length of vector (not including header/trailer)
0x1D - 0x1B Post-shift TCK_SM Count
0x1A - 0x18 Pre-shift TCK_SM Count
0x17 Sync Bit Support Enable
0x16 Macro Structure Bit 8 Enable (Ignored for the shift macros with or without capture)
0x15 Macro Structure bit 7 Enable (Ignored for the shift macros with or without capture)
0x14 - 0x12 Header/Trailer Usage
0x11 Macro Type bit 1
0x10 Macro Type bit 0
0xF - 0x9 Last 7 TMS_SM bits
0x8 Presented during the falling edge of TCK_SM at terminal count during a Shift macro. Use in the same
manner as other TMS bits for State and BIST Macros.
0x7 Loop Bit if Macro type is Shift (for 1149.1 it would be a 0) or BIST
0x6 - 0x0 First 7 TMS_SM Bits (LSB is first bit to be shifted out of TMS_SM)
Table 7. HEADER/TRAILER USAGE
Bit 2 Bit 1 Bit 0 Function
0 0 0 Ignore Headers and Trailers
0 0 1 Use Instruction Header
0 1 0 Use Instruction Trailer
0 1 1 Use both Instruction Header and Trailer
1 0 0 Use Data Header
1 0 1 Use Data Trailer
1 1 0 Use both Data Header and Trailer
1 1 1 Reserved
Table 8. Macro Type bits 10 and 11
Bit 1 Bit 0 Function Function
0 0 BIST Macro Loop on loop bit for Vector count. No Data
0 1 Shift Macro Loop on loop bit for vector count. Read data from TDO_SM memory
1 0 Shift Macro with Capture Loop on loop bit for vector count. Read data from TDO_SM memory
1 1 State Macro Do not loop on loop bit of macro. No data to be shifted
Table 9. SEQUENCER STRUCTURE
Bit(s) Function
0x00 - 0x1F Sequence repeat count (up to 255)
0x20 - 0x2F Vector repeat count
0x30 - 0x3F Vector number
..x.. - ..x.. Repeat vector repeat count and vector number
0x3E0 - 0x3EF Vector repeat count (up to 255)
0x3F0 - 0x3FF Vector number (up to 63)
10 Submit Documentation Feedback Copyright © 2002–2013, Texas Instruments Incorporated
Product Folder Links: SCANSTA101