Reference Guide
12
S6500 Long Range Reader Module - Reference Guide May ’01
2.3.2 Supply Connector (X3)
The supply voltage is connected to connector X3 on the lower circuit board.
2.3.3 Isolated Optocoupler Inputs (X7)
The optocoupler inputs on Terminal X7 are galvanically isolated from the reader elec-
tronics and must therefore be powered by a separate external DC supply. For supply
voltages above 10 V, the input current must be limited to a maximum of 20 mA by an
additional external dropping resistor (see section 3.4.3).
Table 4: Supply Connector
Pin Name Description
1 + 24 V Positive supply
2 GND Ground
Table 5: Supply Connector - Specifications
Parameter Minimum Maximum
Logic Supply Voltage VSL 23.75 V 25.2 V
Logic Supply current ISL - 2.5 A
Connecting Cable Length - 3 m
Ripple (acceptable level) - 20 mV
Table 6: Optocoupler Inputs Connector
Pin Name Description
1 IN1+ + Input 1
2 IN1- - Input 1
3 IN2+ + Input 2
4 IN2- - Input 2
Table 7: Optocoupler Inputs Connector - Specifications
Parameter Minimum Maximum
External Supply Voltage 5 VDC 24 VDC
External Supply Current - 20 mA