4.5 Synchronization
4.5.1 Software Controlled
There is no special wiring required for this type of synchronization. Make sure that
you set the software configuration to No Sync. when you are configuring the reader.
4.5.2 Wireless Synchronization
There are no switch or jumper settings for wireless synchronization. Make sure that
you set the software configuration to wireless synchronization when you are config-
uring the reader.
4.5.3 Wired and Combined Wireless/Wired Synchronization
Figure 10 shows in which way the S251B Reader must be connected for a wired and
a combined wireless/wired synchronization. Make sure that you set the software con-
figuration to match when you are configuring the reader. Table 31 explains the set-
ting of the Synchronization DIP switches 1, 2 & 3.
Figure 10: Wired & Combined Wireless/Wired Sync. Interface Connection
Table 31: Wired and Combined Wireless/Wired Synchronization
Line
Termination
Dip Switch
UNIT 1: UNIT 2...UNIT n-1: UNIT n:
SW1 ON OFF ON
SW2 ON OFF ON
SW3 ON OFF ON (see Note)
Note:
If the distance between Unit 1 and Unit n is less than approximately
400 m, DIP switch SW3 can be left OFF.