4.4.2.1 Activation
The Data Terminal Ready signal (DTR) is connected to the reset/watchdog circuit of
the S251B Reader. This ensures a PC controlled microcomputer initialization before
the default Read Mode is started.
When power is applied to the reader the Data Set Ready signal (DSR) of the RS232-
C interface is activated.
4.4.3 RS422
Connect the WECO (marked RS422 / 485) connector as shown in Table 30. Set the
switches as shown in Figure 8. If you are only using one reader the line terminal
switch 3 must be switched to ON, if you are using more than one reader only the last
reader in the line must be switched to ON (all other readers to OFF).
5 GND Signal Ground -
6 DSR Data Set Ready Output
7 - Not connected -
8 - Not connected -
9 - Not connected -
Table 29: RS232 WECO Connector
Pin Signal Description Direction
1 RxD Receive Data Input
2 DTR Data Terminal Ready Input
3 GND Signal Ground -
4 TxD Transmit Data Output
5 DSR Data Set Ready Output
6 GND Signal Ground -
Table 28: RS232 9-pin Connector
Pin Signal Description Direction