Product Info
Table Of Contents
- 1.1 Description
- Summary of Chapters and Appendixes
- 2.1 General Specification
- 3.1 Reader Panel Configurations
- Typical Reader Installation Steps
- FCC Part 15 Compliance
- 4.2 ETSI Conformity
- 4.3 CE Conformity
- 4.4 Environmental Requirements
- 4.5 Warranty and Liability
- RF Exposure "Caution" Label
- RF Exposure "Caution" Sign
August 2001 Series 7000 Reader Reference Guide
24
Draft Document
FCC ID: A92RU1001A
- Thermal Shock: Thermal Shock testing in accordance with MIL-STD-810E, Method 503.3,
using the following thermal shock parameters: - 45 to 85 degrees C, 100 cycles duration, 30
minutes per temperature.
- Mechanical Shock Environment: Shock test performed in accordance with MIL-STD-810E,
Method 516.3 using the following parameters: 5 G's at 10 ms, half-sinusoidal wave, 6 axes,
and 3 shocks per axis.
- Vibration Environment: Vibration tests in accordance with MIL-STD-810E, Method 514.4,
using the following parameters: 15 to 500 Hz, 1-g peak, 30 minutes sweep, logarithmic.
4.5 Warranty and Liability
The "General Conditions of Sale and Delivery" of Texas Instruments Incorporated or a TI
subsidiary apply. Warranty and liability claims for defect products, injuries to persons and
property damages are void if they are the result of one or more of the following causes:
! Improper use of the reader module.
! Unauthorized assembly, operation and maintenance of the reader module.
! Operation of the reader modules with defective and/or non-functioning safety and
protective equipment.
! Failure to observe the instructions during transport, storage, assembly, operation,
maintenance and setting up of the reader modules.
! Unauthorized changes to the reader modules.
! Insufficient monitoring of the reader modules' operation or environmental conditions.
! Improperly conducted repairs.
! Catastrophes caused by foreign bodies and acts of God.