2.1 General Specification
This chapter describes the electrical and mechanical specifications of the Series 7000 RI-RU1-001A-
00 reader. Operating at a frequency of 915 MHz, this low profile device is designed to be easily
integrated into many logistics management systems and supports as many as nine antennas through
nine separate coaxial connectors. All reader I/O is accomplished through the use of a DB-9F
connector, to include all communication, which is asynchronous RS232 as controlled by a host
system. The reader also has a DB-25 connector that is intended for general diagnostic functions.
Specification
Operating Frequency: 915 MHz
LEDs: One Power ON LED, one Transmit ON LED, and one Activity/Error LED
Communication Method: RS-232
Serial Transmission Rate: Up to 57,600 bps
Connectors: One Female DB-9F for RS-232 communications
One DB-25 for diagnostic use
DB9F Pin Assignments: Pin 1 _ Not used
Pin 2 - Transmit Data (Input)
Pin 3 - Receive Data (Output)
Pin 4 - Internally connected to Pin 6
Pin 5 - Protective Ground
Pin 6 - Internally connected to Pin 4
Pin 7 - Internally connected to Pin 8
Pin 8 - Internally connected to Pin 7
Pin 9 - Protective Ground
Power Input: 12 V, 3 Amps
RF Output Power: 1 Watt
Power Consumption: 15 watts
Ambient Operating
Temperature: 0° to 50° C (32° to 122° F)
Maximum Serial
Cable Length: 10 meters (30 Feet)
Dimensions: 36 cm x 20 cm x 11 cm
(14 in x 8 in x 4.5 in)
Weight: 3 Kg (7 lbs.)
CAUTION:
The Series 7000 reader is an intentional radiator, and when
integrated, the integrator is subject to meeting FCC Part
15, Subpart C, and similar tenets under European
Standard EN 300330.