Powering Up the EVM and Taking Measurements
replace R5 (120- default) with 60
replace R8 and R9 (0- default) with 375
connect pin 2 of JMP7 with pin 1 and pin 3 with pin 4
replace the previous wire-bridge at TB1 with a second power supply unit (PSU2) and connect the
ground terminals of both, PSU1 and PSU2 with a wire-bridge, as shown in Figure 8.
Figure 8. RS-485 Half-Duplex EVM Setup for Maximum Loading
Note that Figure 8 only shows the wiring of PSU2 for positive common-mode voltages. For negative
V
CM
, connect the ground terminal of PSU2 with pin 1 of TB1 (EARTH), and the V
CM
-output of PSU2
with the ground terminal of PSU1.
Figure 9. RS-485 Half-Duplex EVM Configurations: Left as Receiver EVM, Right as Transmitter EVM
7
SLLU173BOctober 2012Revised June 2013 RS-485 Half-Duplex Evaluation Module
Submit Documentation Feedback