Datasheet

RC4558
www.ti.com
SLOS073F MARCH 1976REVISED SEPTEMBER 2010
Absolute Maximum Ratings
(1)
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
CC+
18
Supply voltage
(2)
V
V
CC
18
V
ID
Differential input voltage
(3)
±30 V
V
I
Input voltage (any input)
(2) (4)
±15 V
Duration of output short circuit to ground, one amplifier at a time
(5)
Unlimited
D package 97
DGK package 172
θ
JA
Package thermal impedance
(6) (7)
P package 85 °C/W
PS package 95
PW package 149
T
J
Operating virtual junction temperature 150 °C
T
stg
Storage temperature range 65 150 °C
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating
Conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values, unless otherwise noted, are with respect to the midpoint between V
CC+
and V
CC
.
(3) Differential voltages are at IN+ with respect to IN.
(4) The magnitude of the input voltage must never exceed the magnitude of the supply voltage or 15 V, whichever is less.
(5) Temperature and/or supply voltages must be limited to ensure that the dissipation rating is not exceeded.
(6) Maximum power dissipation is a function of T
J
(max), θ
JA
, and T
A
. The maximum allowable power dissipation at any allowable ambient
temperature is P
D
= (T
J
(max) T
A
)/θ
JA
. Operating at the absolute maximum T
J
of 150°C can affect reliability.
(7) The package thermal impedance is calculated in accordance with JESD 51-7.
Recommended Operating Conditions
MIN MAX UNIT
V
CC+
5 15
Supply voltage V
V
CC
5 15
RC4558 0 70
T
A
Operating free-air temperature °C
RC4558I 40 85
Copyright © 19762010, Texas Instruments Incorporated 3