Datasheet
Table Of Contents
- FEATURES
- APPLICATIONS
- DESCRIPTION
- ABSOLUTE MAXIMUM RATINGS
- ELECTRICAL CHARACTERISTICS
- ELECTRICAL CHARACTERISTICS
- DEVICE INFORMATION
- PTH12030W TYPICAL CHARACTERISTICS (VI = 12 V)Characteristic data has been developed from actual products tested at 25C. This data is considered typical data for the converter. Applies to , , and .SOA curves represent the conditions at which internal components are at or below the manufacturer’s maximum operating temperatures. Derating limits apply to modules soldered directly to a 4 in. 4 in. double-sided PCB with 1 oz. copper. For surface mount products (AS and AZ suffix), multiple vias (plated through holes) are required to add thermal paths around the power pins. Please refer to the mechanical specification for more information. Applies to .
- PTH12030L TYPICAL CHARACTERISTICS (VI = 12 V)Characteristic data has been developed from actual products tested at 25C. This data is considered typical data for the converter. Applies to , , and .SOA curves represent the conditions at which internal components are at or below the manufacturer’s maximum operating temperatures. Derating limits apply to modules soldered directly to a 4 in. 4 in. double-sided PCB with 1 oz. copper. For surface mount products (AS and AZ suffix), multiple vias (plated through holes) are required to add thermal paths around the power pins. Please refer to the mechanical specification for more information. Applies to .
- APPLICATION INFORMATION
- TAPE AND REEL SPECIFICATIONS
- TRAY SPECIFICATIONS

t − Time − 10 ms/div
V
O
1 (1 V/div)
V
O
2 (1 V/div)
I
O
2 (5 V/div)
PTH12030W/L
SLTS211H – MAY 2003 – REVISED DECEMBER 2008 ....................................................................................................................................................
www.ti.com
CONDITIONS FOR PREBIAS HOLDOFF
In order for the module to allow an output prebias voltage to exist (and not sink current), certain conditions must
be maintained. The module holds off a prebias voltage when the Inhibit pin is held low, and whenver the output is
allowed to rise under soft-start control. Power up under soft-start control occurs upon the removal of the ground
signal to the Inhibit pin (with input voltage applied), or when input power is applied with Auto-Track disabled.
[2]
To
further ensure that the regulator doesn ’ t sink output current, (even with a ground signal applied to its Inhibit), the
input voltage must always be greater than the applied prebias source. This condition must exist throughout the
power-up sequence.
[3]
The soft-start period is complete when the output begins rising above the prebias voltage. Once it is complete,
the module functions as normal, and sinks current if voltage higher than the nominal regulation value is applied
to its output.
Note: If a prebias condition is not present, the soft-start period is complete when the output voltage has risen
to either the set-point voltage, or the voltage applied at the module ’ s Track control pin, whichever is lowest.
DEMONSTRATION CIRCUIT
Figure 19 shows the startup waveforms for the demonstration circuit shown in Figure 20 . The initial rise in V
O
2 is
the prebias voltage, which is passed from the VCCIO to the VCORE voltage rail through the ASIC. Note that the
output current from the PTH12010L module (I
O
2) is negligible until its output voltage rises above the applied
prebias.
Figure 19. Prebias Startup Waveforms
NOTES
1. Output prebias holdoff is an inherent feature to all PTH120x0L and PTV120x0W/L modules. It has now been
incorporated into all modules (including W-suffix modules with part numbers of the form PTH120x0W), with a
production lot date code of 0423 or later.
2. The prebias start-up feature is not compatible with Auto-Track. If the rise in the output is limited by the
voltage applied to the Track control pin, the output sinks current during the period that the track control
voltage is below that of the back-feeding source. For this reason, it is recommended that Auto-Track be
disabled when not being used. This is accomplished by connecting the Track pin to the input voltage, V
I
. This
raises the Track pin voltage well above the set-point voltage prior to the module ’ s start up, thereby defeating
the Auto-Track feature.
3. To further ensure that the regulator ’ s output does not sink current when power is first applied (even with a
ground signal applied to the Inhibit control pin), the input voltage must always be greater than the applied
prebias source. This condition must exist throughout the power-up sequence of the power system.
18 Submit Documentation Feedback Copyright © 2003 – 2008, Texas Instruments Incorporated