Datasheet
UNDERVOLTAGE LOCKOUT (UVLO)
R
UVLO
+
9690 *
ǒ
137 V
I
Ǔ
ǒ
137 V
I
Ǔ
* 585
(
kW
)
(5)
2
3 4
11
Inhibit/
UVLO Prog
GND
GND
V
I
V
I
R
UVLO
C
I
PTH08T240W/241W
PTH08T240W , PTH08T241W
SLTS264J – NOVEMBER 2005 – REVISED JUNE 2009 ...................................................................................................................................................
www.ti.com
The PTH08T240/241W power modules incorporate an input undervoltage lockout (UVLO). The UVLO feature
prevents the operation of the module until there is sufficient input voltage to produce a valid output voltage. This
enables the module to provide a clean, monotonic powerup for the load circuit, and also limits the magnitude of
current drawn from the regulator ’ s input source during the power-up sequence.
The UVLO characteristic is defined by the ON threshold (V
THD
) voltage. Below the ON threshold, the Inhibit
control is overridden, and the module does not produce an output. The hysteresis voltage, which is the difference
between the ON and OFF threshold voltages, is set at 500 mV. The hysteresis prevents start-up oscillations,
which can occur if the input voltage droops slightly when the module begins drawing current from the input
source.
The UVLO feature of the PTH08T240/241W module allows for limited adjustment of the ON threshold voltage.
The adjustment is made via the Inhbit/UVLO Prog control pin (pin 11) using a single resistor (see Figure 20 ).
When pin 11 is left open circuit, the ON threshold voltage is internally set to its default value, which is 4.3 volts.
The ON threshold might need to be raised if the module is powered from a tightly regulated 12-V bus. Adjusting
the threshold prevents the module from operating if the input bus fails to completely rise to its specified
regulation voltage.
Equation 5 determines the value of R
UVLO
required to adjust V
THD
to a new value. The default value is 4.3 V, and
it may only be adjusted to a higher value.
Table 7 shows a chart of standard resistor values for R
UVLO
for different options of the on-threshold (V
THD
)
voltage.
Table 7. Standard R
UVLO
values for Various V
THD
values
V
THD
(V) 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0 10.5 11.0
R
UVLO
(k Ω ) 88.7 52.3 37.4 28.7 23.2 19.6 16.9 14.7 13.0 11.8 10.5 9.76 8.87
Figure 20. Undervoltage Lockout Adjustment Resistor Placement
22 Submit Documentation Feedback Copyright © 2005 – 2009, Texas Instruments Incorporated
Product Folder Link(s): PTH08T240W PTH08T241W