Datasheet
TYPICAL CHARACTERISTICS
(1) (2)
CHARACTERISTIC DATA (V
I
= 5 V)
0 2 4 6 8 10
0
0.5
1.0
2.0
1.5
2.5
1.1 V
2.0 V
0.9 V
I
O
- Output Current - A
P
D
- Power Dissipation - W
2.0
1.1
0.9
V
O
(V)
V
I
= 5 V
0
0
2 4 6 8 10
2
6
4
12
8
10
2.0
1.1
0.9
V
O
(V)
1.1 V
0.9 V
2.0 V
V
I
= 5 V
V
O
– Output Voltage Ripple – V
PP(mV)
I
O
- Output Current - A
0 2 4 6 8 10
I
O
- Output Current - A
1.1 V
0.9 V
2.0 V
V
I
= 5 V
2.0
1.1
0.9
V
O
(V)
50
70
65
75
80
85
95
90
100
h - Efficiency - %
60
55
0 2 4 6 8 10
20
40
30
50
70
60
90
80
Natural
Convection
V
I
= 5 V
All V
O
I
O
- Output Current - A
TA - Ambient Temperature - °C
PTH08T240F
www.ti.com
............................................................................................................................................... SLTS277D – DECEMBER 2006 – REVISED MARCH 2009
EFFICIENCY OUTPUT RIPPLE POWER DISSIPATION
vs vs vs
LOAD CURRENT LOAD CURRENT LOAD CURRENT
Figure 1. Figure 2. Figure 3.
SAFE OPERATING AREA
Figure 4.
(1) The electrical characteristic data has been developed from actual products tested at 25 ° C. This data is considered typical for the
converter. Applies to Figure 1 , Figure 2 , and Figure 3 .
(2) The temperature derating curves represent the conditions at which internal components are at or below the manufacturer ' s maximum
operating temperatures. Derating limits apply to modules soldered directly to a 100 mm x 100 mm double-sided PCB with 2 oz. copper.
For surface mount packages (AS and AZ suffix), multiple vias must be utilized. Please refer to the mechanical specification for more
information. Applies to Figure 4 .
Copyright © 2006 – 2009, Texas Instruments Incorporated Submit Documentation Feedback 7
Product Folder Link(s): PTH08T240F