Datasheet
www.ti.com
t − 20 ms/div
V
O
Bus (1 V/div)
t
d
= 20 ms
V
(POL)
2 (1 V/div)
V
O
Seq (1 V/div)
V
(POL)
1 (1 V/div)
PTB78560A , PTB78560B
PTB78560C
SLTS249 – JUNE 2005
must always be set to 3.3 V (R1 = 5.36 k Ω ). This sets the output voltage of both the V
O
Bus and V
O
Seq outputs.
The output voltage of the 3.3-V input (nonisolated) modules, U2 and U3, can be set to any voltage over the
range, 0.8 V to 2.5 V. In this example, they are set to 2.5 V (R2 = 2.32 k Ω ) and 1.8 V (R3 = 6.65 k Ω ),
respectively. Figure 27 shows the power-up waveforms from Figure 28 when the Track input to all three modules
are simply connected together.
The converter provides input power to the downstream nonisolated modules via the V
O
Bus output. This output
rises first to allow the nonisolated modules to complete their power-up initialization. The V
O
Seq (3.3 V), V
(POL)
1
(2.5 V) and V
(POL)
2 (1.8 V), outputs supply the load circuit, and rise simultaneously when the converter removes
the internal ground signal to its own Track input. The V
O
Seq output rises with the outputs from the nonisolated
modules, until it reaches its set-point voltage.
Figure 27. Power-Up Waveforms with POL Modules
19