Datasheet

www.ti.com
Controlling the PGA450-Q1 Memory Spaces With the GUI
Figure 8. Echo Data Stored in FIFO RAM Plotted in Excel
10.7.2 EVAL Monitor
This tab graphs the output of the digital data path directly in the GUI. The 8051W microcontroller must be
in reset to use this tab.
10.7.2.1 No. of Loops
This option selects how many times the GUI will transmit a burst and plot the echo data.
10.7.2.2 Trigger
If "Auto" is displayed, the GUI will continue sending bursts and plotting the echo data until the "Loops
Complete" count matches the "No. of Loops." If "USER" is displayed, the GUI will stop and wait for the
user to press the green flashing "Trigger" button before continuing.
10.7.2.3 Resolution
This button has three options, "FULL", "1/2", and "1/4". The "FULL" setting plots all of the echo data
points, but takes more time. The "1/2" and "1/4" options reduce the number of data points plotted which
results in faster plotting.
10.7.2.4 Clear Plot
The "CLR" button clears all data from the graph. If the "Clear Plot" option is checked, echo data will be
cleared from the plot every loop. If "Clear Plot" is not checked, every loop will plot the new echo data in a
new color on top of the existing data on the graph.
15
SLDU007AMarch 2012Revised January 2013 PGA450-Q1 EVM User’s Guide
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated