Datasheet
PCM9211
www.ti.com
SBAS495 –JUNE 2010
Register 39h, Incoming Biphase Information and Sampling Frequency
(Address: 39h, Read-Only)
DATA B7 B6 B5 B4 B3 B2 B1 B0
Reg Name SFSST SCSBIT1 RSV RSV SESOUT3 SESOUT2 SESOUT1 SESOUT0
Default Value N/A N/A N/A N/A N/A N/A N/A N/A
Memo
SFSST: Incoming Biphase Signal, Sampling Frequency Calculate Status
0: SFSOUT[3:0] Output is calculated
1: In the process of calculating or unlocked
SCSBIT1: Detected Channel Status Bit1 Flag
0: CS Bit1 = 0 (Audio data)
1: CS Bit1 = 1 (Non-audio data)
SFSOUT[3:0]: Incoming Biphase Signal, Actual Sampling Frequency
0000: Out of range
0001: 8 kHz
0010: 11.025 kHz
0011: 12 kHz
0100: 16 kHz
0101: 22.05 kHz
0110: 24 kHz
0111: 32 kHz
1000: 44.1 kHz
1001: 48 kHz
1010: 64 kHz
1011: 88.2 kHz
1100: 96 kHz
1101: 128 kHz
1110: 176.4 kHz
1111: 192 kHz
NOTE
When SFSST becomes '1' (that is, in the process of calculating or unlocked), SFSOUT
holds the previous data. SFSST and SFSOUT always output the status when these
registers are read. The other registers do not have clear functions when these are read.
To enable these registers, DIR must be powered on (Register 40h/RXDIS = 0).
Copyright © 2010, Texas Instruments Incorporated Submit Documentation Feedback 85
Product Folder Link(s): PCM9211