Datasheet

PCM5141, PCM5142
www.ti.com
SLAS759A AUGUST 2012REVISED SEPTEMBER 2012
Table 47. Control Interface Timing
Parameters Min Max Units
t
MCY
MC Pulse Cycle Time 100
t
MCL
MC Low Level Time 40
t
MCH
MC High Level Time 40
t
MHH
MS High Level Time 20
t
MSS
MS Edge to MC Edge 30 ns
t
MSH
MS Hold Time
(1)
30
t
MDH
MDI Hold Time 15
t
MDS
MDI Set-up Time 15
t
MOS
MC Rise Edge to MDO Stable 20
(1) MC falling edge for LSB to MS rising edge.
Copyright © 2012, Texas Instruments Incorporated Submit Documentation Feedback 71
Product Folder Links: PCM5141 PCM5142