PCM5100, PCM5101, PCM5102
SLAS764B MAY 2011REVISED SEPTEMBER 2012
www.ti.com
Normal x2 / x1(bypass) Interpolation filter is programmed in 256 cycles in 1 sample time (t
S
) for sample rates
from 8kHz to 384kHz.
Table 11. Normal x2 Interpolation Filter
Parameter Condition Value (Typ) Value (Max) Units
Filter Gain Pass Band 0 ……. 0.45f
S
±0.02 dB
Filter Gain Stop Band 0.55f
S
….. 7.455f
S
–60 dB
Filter Group Delay 22t
S
s
Figure 22. Normal x2 Interpolation Filter Frequency Figure 23. Normal x2 Interpolation Filter Impulse
Response Response
Figure 24. Normal x2 Interpolation Filter Passband Ripple
18 Submit Documentation Feedback Copyright © 2011–2012, Texas Instruments Incorporated
Product Folder Links: PCM5100 PCM5101 PCM5102