RESET OPERATION
The PCM4204 includes two reset functions: power-on and
externally controlled. This section describes the operation
of each of these functions.
On power-up, the internal reset signal is forced low, forcing
the PCM4204 into a reset state. The power-on reset circuit
monitors the V
DD
1, V
DD
2, V
DD
3, V
CC
1, and V
CC
2 power
supply. When the V
DD
supply exceeds +2.0V (±400mV)
and V
DD
1 and V
DD
2 supply exceeds +4.0V (±400mV), the
internal reset signal is forced high. The PCM4204 then
waits for the system clock input (SCKI) to become active.
Once the system clock has been detected, the initialization
sequence begins. The initialization sequence requires
1024 system clock periods for completion. During the
initialization sequence, the ADC output data pins are
forced low. Once the initialization sequence is completed,
the PCM4204 output is enabled. Figure 11 shows the
power-on reset sequence timing.
The user may force a reset initialization sequence at any
time while the system clock input is active by utilizing the
RST
input (pin 10). The RST input is active low, and
requires a minimum low pulse width of 40ns. The
low-to-high transition of the applied reset signal forces an
initialization sequence to begin. As in the case of the
power-on reset, the initialization sequence requires 1024
system clock periods for completion. Figure 12 illustrates
the reset sequence initiated when using the RST
input.
Figure 13 shows the state of the audio data outputs for the
PCM4204 before, during and after the reset operations.
1024 System Clock Periods
Required for Initialization
System Clock
Indeterminate
or Inactive
SCKI
~2.0V
~4.0V
0V
0V
0V
0V
Internal
Reset
V
CC
1
V
CC
2
V
DD
1
V
DD
2
V
DD
3
Figure 11. Power-On Reset Sequence