Datasheet
SBAS290B − JULY 2003 − SEPTEMBER 2004
www.ti.com
6
ELECTRICAL CHARACTERISTICS (continued)
All parameters are specified at T
A
= +25°C with V
CC
= +5V, V
DD
= +3.3V, and a measurement bandwidth from 20Hz to 20kHz, unless otherwise
noted. System clock frequency is equal to 256f
S
for Single and Dual Rate sampling modes, and 128f
S
for Quad Rate sampling mode.
PCM4202
PARAMETER UNITSMAXTYPMINCONDITIONS
DIGITAL DECIMATION FILTER
Passband edge Single and Dual Rate 0.453f
S
Hz
Passband ripple Single and Dual Rate ±0.005 dB
Passband edge Single and Dual Rate 0.547f
S
Hz
Stop band attenuation Single and Dual Rate −100 dB
Group delay Single and Dual Rate 37/f
S
sec
Passband edge (−0.005dB) Quad Rate 0.375f
S
Hz
−3dB cutoff frequency Quad Rate 0.490f
S
Hz
Passband ripple Quad Rate ±0.005 dB
Passband edge Quad Rate 0.770f
S
Hz
Stop band attenuation Quad Rate −135 dB
Group delay Quad Rate 9.5/f
S
sec
DIGITAL HIGH PASS FILTER
Frequency response (−3dB) f
S
/48000 Hz
POWER SUPPLY
Voltage range V
CC
+4.75 +5.0 +5.25 VDC
V
DD
+3.0 +3.3 +3.6 VDC
Operating supply current V
CC
= +5V, V
DD
= +3.3V
f
S
= 48kHz, Single Rate 55 65 mA
f
S
= 96kHz, Dual Rate 55 65 mA
f
S
= 192kHz, Quad Rate 55 65 mA
I
DD
V
CC
= +5V, V
DD
= +3.3V
f
S
= 48kHz, Single Rate 10 12 mA
f
S
= 96kHz, Dual Rate 19 25 mA
f
S
= 192kHz, Quad Rate 13 15 mA
Power-down mode current V
CC
= +5V, V
DD
= +3.3V, RST = 0
I
CC
Clocks applied 10 mA
I
DD
Clocks applied 2 mA
Total power dissipation V
CC
= +5V, V
DD
= +3.3V
f
S
= 48kHz, Single Rate 308 365 mW
f
S
= 96kHz, Dual Rate 338 408 mW
f
S
= 192kHz, Quad Rate 318 375 mW
(1)
Applies to the RST input, pin 19.
(2)
Single, Dual, and Quad Rate sampling modes are described within this data sheet.
(3)
Dynamic performance parameters are measured using an Audio Precision System Two Cascade or Cascade Plus test system. The
measurement bandwidth is limited by using the Audio Precision 22Hz high-pass filter in combination with the Audio Precision 20kHz, f
S
/2, or
a user-defined 40kHz low-pass filter. All A-weighted measurements are performed using the Audio Precision A-weighting filter in combination
with the previously mentioned filters.