Datasheet


SBAS290BJULY 2003 − SEPTEMBER 2004
www.ti.com
4
ELECTRICAL CHARACTERISTICS
All parameters are specified at T
A
= +25°C with V
CC
= +5V, V
DD
= +3.3V, and a measurement bandwidth from 20Hz to 20kHz, unless otherwise
noted. System clock frequency is equal to 256f
S
for Single and Dual Rate sampling modes, and 128f
S
for Quad Rate sampling mode.
PCM4202
PARAMETER CONDITIONS MIN TYP MAX UNITS
RESOLUTION 24 Bits
AUDIO DATA FORMAT
Linear PCM interface formats Two’s complement, MSB first data I
2
S, Left or Right Justified
Linear PCM word length 24 Bits
Direct Stream Digital (DSD) output 1 Bit
DIGITAL CHARACTERISTICS
Input logic level V
IH
0.7 x V
DD
V
DD
V
V
IL
0 0.3 x V
DD
V
Output logic level V
OH
I
OH
= −2mA 0.8 x V
DD
V
V
OL
I
OL
= +2mA 0.2 x V
DD
V
Input current I
IH
V
IN
= V
DD
+10 µA
I
IL
V
IN
= 0V −10 µA
Input current
(1)
I
IH
V
IN
= V
DD
+25 µA
I
IL
V
IN
= 0V −25 µA
Single rate 8 54 kHz
Sampling frequency
(2)
f
S
Dual rate 54 108 kHz
Sampling frequency
f
S
Quad rate 108 216 kHz
System clock duty cycle 45 50 55 %
Single rate, SCKI = 256f
S
2.048 13.824 MHz
Single rate, SCKI = 384f
S
3.072 20.736 MHz
Single rate, SCKI = 512f
S
4.096 27.648 MHz
System clock frequency
(2)
Single rate, SCKI = 768f
S
6.144 38.4 MHz
System clock frequency
(2)
Dual rate, SCKI = 256f
S
13.824 27.648 MHz
Dual rate, SCKI = 384f
S
20.736 38.4 MHz
Quad rate, SCKI = 128f
S
13.824 27.648 MHz
Quad rate, SCKI = 192f
S
20.736 38.4 MHz
ANALOG OUTPUTS
Input voltage, full-scale Differential input 6.0 V
PP
Input impedance 3 k
Common-mode rejection 85 dB
DC PERFORMANCE
Output offset error HPFD = 1 ±4 % of FSR
Gain error ±4 % of FSR
Gain mismatch channel-to-channel ±3 % of FSR
(1)
Applies to the RST input, pin 19.
(2)
Single, Dual, and Quad Rate sampling modes are described within this data sheet.
(3)
Dynamic performance parameters are measured using an Audio Precision System Two Cascade or Cascade Plus test system. The
measurement bandwidth is limited by using the Audio Precision 22Hz high-pass filter in combination with the Audio Precision 20kHz, f
S
/2, or
a user-defined 40kHz low-pass filter. All A-weighted measurements are performed using the Audio Precision A-weighting filter in combination