Datasheet
PCM3010
SLES055 – NOVEMBER 2002
16
www.ti.com
–45
–40
–35
–30
–105
–100
–95
–90
16 32 48 64 80 96 112
f
S
– Sampling Frequency – kHz
THD+N – Total Harmonic Distortion + Noise at 0 dB – dB
TOTAL HARMONIC DISTORTION + NOISE
vs
SAMPLING FREQUENCY
THD+N – Total Harmonic Distortion + Noise at –60 dB – dB
–60 dB
0 dB
Figure 30
95
100
105
110
16 32 48 64 80 96 112
f
S
– Sampling Frequency – kHz
Dynamic Range and SNR – dB
DYNAMIC RANGE and SNR
vs
SAMPLING FREQUENCY
SNR
Dynamic Range
Figure 31
All specifications at T
A
= 25°C, V
CC
1 = V
CC
2 = 5 V, V
DD
= 3.3 V, f
S
= 44.1 kHz, SCKI = 384 f
S