RECOMMENDED OPERATING CONDITIONS
PCM3000
PCM3001
SBAS055A – OCTOBER 2000 – REVISED OCTOBER 2004
over operating free-air temperature range (unless otherwise noted)
MIN NOM MAX UNIT
Analog supply voltage, V
CC
1, V
CC
2 4.5 5 5.5 VDC
Digital supply voltage, V
DD
4.5 5 5.5 VDC
Analog input voltage, full scale (–0 dB) 2.9 Vp-p
Digital input logic family TTL
System clock 8.192 24.576 MHz
Digital input clock frequency
Sampling clock 32 48 kHz
Analog output load resistance 5 k Ω
Analog output load capacitance 50 pF
Digital output load capacitance 10 pF
Operating free-air temperature, T
A
–25 85 ° C