Datasheet
www.ti.com
ABSOLUTE MAXIMUM RATINGS
RECOMMENDED OPERATING CONDITIONS
PCM1804
SLES022C – DECEMBER 2001 – REVISED OCTOBER 2007
over operating free-air temperature range (unless otherwise noted)
(1)
V
CC
– 0.3 V to 6.5 V
Supply voltage
V
DD
– 0.3 V to 4 V
Ground voltage differences AGND, AGNDL, AGNDR, DGND ± 0.1 V
Supply voltage difference V
CC
, V
DD
V
CC
– V
DD
< 3 V
FMT0, FMT1, S/ M, OSR0, OSR1, OSR2, SCKI, RST – 0.3 V to 6.5 V
Digital input voltage
BYPAS, DATA/DSDR, BCK/DSDL, LRCK/DSDBCK, OVFL, OVFR – 0.3 V to (V
DD
+ 0.3 V)
Analog input voltage V
REF
L, V
REF
R, V
COM
L, V
COM
R, V
IN
L+, V
IN
R+, V
IN
L – , V
IN
R – – 0.3 V to (V
CC
+ 0.3 V)
Input current (any pins except supplies) ± 10 mA
T
A
Ambient temperature under bias – 40 ° C to 125 ° C
T
stg
Storage temperature – 55 ° C to 150 ° C
T
J
Junction temperature 150 ° C
Lead temperature (soldering) 260 ° C, 5 s
Package temperature (IR reflow, peak) 260 ° C
(1) Stresses beyond those listed under "absolute maximum ratings ” may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions ” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
over operating free-air temperature range
MIN NOM MAX UNIT
Analog supply voltage, V
CC
4.75 5 5.25 V
Digital supply voltage, V
DD
3 3.3 3.6 V
Analog input voltage, full-scale ( – 0 dB), differential input 5 Vp-p
Digital input logic family TTL compatible
System clock 8.192 36.864 MHz
Digital input clock frequency
Sampling clock 32 192 kHz
Digital output load capacitance 10 pF
Operating free-air temperature, T
A
– 10 70 ° C
Copyright © 2001 – 2007, Texas Instruments Incorporated Submit Documentation Feedback 5
Product Folder Link(s): PCM1804