Datasheet

www.ti.com
LINEAR PHASE ANTIALIAS DIGITAL FILTER FREQUENCY RESPONSE - Quad-Rate
Normalized Frequency − y f
S
−200
−150
−100
−50
0
50
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Amplitude − dB
G024
f
S
= 192 kHz
Normalized Frequency − y f
S
−150
−140
−130
−120
−110
−100
−90
−80
−70
−60
−50
−40
−30
−20
−10
0
0.00 0.25 0.50 0.75 1.00
Amplitude − dB
G025
f
S
= 192 kHz
Normalized Frequency − y f
S
−0.10
−0.08
−0.06
−0.04
−0.02
0.00
0.02
0.0 0.1 0.2 0.3 0.4 0.5 0.6
Amplitude − dB
G026
f
S
= 192 kHz
Normalized Frequency − y f
S
−10
−9
−8
−7
−6
−5
−4
−3
−2
−1
0
0.45 0.47 0.49 0.51 0.53 0.55
Amplitude − dB
G027
f
S
= 192 kHz
−3.9 dB at 0.5 f
S
PCM1804
SLES022C DECEMBER 2001 REVISED OCTOBER 2007
TYPICAL PERFORMANCE CURVES OF INTERNAL FILTER (continued)
OVERALL CHARACTERISTICS STOP-BAND ATTENUATION CHARACTERISTICS
FOR QUAD-RATE FILTER FOR QUAD-RATE FILTER
Figure 24. Figure 25.
PASS-BAND RIPPLE CHARACTERISTICS TRANSIENT BAND CHARACTERISTICS
FOR QUAD-RATE FILTER FOR QUAD-RATE FILTER
Figure 26. Figure 27.
Copyright © 2001 2007, Texas Instruments Incorporated Submit Documentation Feedback 15
Product Folder Link(s): PCM1804