Datasheet
www.ti.com
PIN ASSIGNMENTS
1
2
3
4
5
6
7
8
9
10
20
19
18
17
16
15
14
13
12
11
V
IN
L
V
IN
R
V
REF
1
V
REF
2
V
CC
AGND
PDWN
BYPAS
FSYNC
LRCK
MODE1
MODE0
FMT1
FMT0
OSR
SCKI
V
DD
DGND
DOUT
BCK
PCM1802
(TOP VIEW)
P0009-02
Single-End
/Differential
Converter
BCK
V
IN
L
Reference
Single-End
/Differential
Converter
V
REF
1
V
REF
2
V
IN
R
5
th
Order
Delta-Sigma
Modulator
5
th
Order
Delta-Sigma
Modulator
×1/64 (×1/128)
Decimation
Filter
with
High-Pass Filter
Power Supply
AGNDV
CC
V
DD
DGND
Clock and Timing Control
Serial
Interface
Mode/
Format
Control
LRCK
FSYNC
DOUT
FMT0
FMT1
MODE0
MODE1
BYPAS
OSR
PDWN
SCKI
B0004-07
PCM1802
SLES023C – DECEMBER 2001 – REVISED JANUARY 2005
This device contains circuits to protect its inputs and outputs against damage due to high static voltages
or electrostatic fields. These circuits have been qualified to protect this device against electrostatic
discharges (ESD) of up to 2 kV according to MIL-STD-883C, Method 3015; however, it is advised that
precautions be taken to avoid application of any voltage higher than maximum-rated voltages to these
high-impedance circuits. During storage or handling, the device leads should be shorted together or the
device should be placed in conductive foam. In a circuit, unused inputs should always be connected to
an appropriated logic voltage level, preferably either V
CC
or ground. Specific guidelines for handling
devices of this type are contained in the publication Electrostatic Discharge (ESD) (SSYA010 ) available
from Texas Instruments.
BLOCK DIAGRAM