Datasheet

TYPICAL CIRCUIT CONNECTION DIAGRAM
S0012-01
1
2
3
4
5
6
7
8
9
10
11
12
24
23
22
21
20
19
18
17
16
15
14
13
SYSCLK
DOUT
BCK
LRCK
RSTB
BYPAS
FMT0
FMT1
MODE0
MODE1
SYNC
+
4.7 µF
+
1.0 µF
(2)
Analog
Front-End
Delta-Sigma
Decimation Filter
Digital Audio Interface
Reset
Clock
Audio
Data
Processor
Pin Program
or Control
Line In Left-Channel
+
1.0 µF
(2)
Line In Right-Channel
GND
+5 V
+
4.7 µF
Ref
0.1 µF/10 µF
(1)
0.1 µF/10 µF
(1)
+
+
C
EXT
470 pF
C
EXT
470 pF
Signal Gnd
Analog
Front-End
PCM1800
www.ti.com
............................................................................................................................................... SBAS071B OCTOBER 2000 REVISED AUGUST 2008
Figure 28 is a typical circuit connection diagram for which the cutoff frequency of the input HPF is about 5 Hz.
(1) Bypass capacitor = 0.1- µ F ceramic and 10- µ F tantalum, depending on layout and power supply.
(2) A 1- µ F capacitor gives a 5.3-Hz cutoff frequency for the input HPF in normal operation and requires a power-on
settling period with a 30-ms time constant during power-on initialization.
Figure 28. Typical Circuit Connection
Copyright © 2000 2008, Texas Instruments Incorporated Submit Documentation Feedback 21
Product Folder Link(s): PCM1800