Datasheet


SLES105BFEBRUARY 2004 − REVISED NOVEMBER 2006
www.ti.com
25
TIMING DIAGRAM
S
DA
S
CL
t
(BUF)
t
(D-SU)
t
(D-HD)
Start
t
(LOW)
t
(S-HD)
t
(SCL-F)
t
(SCL-R)
t
(HI)
Repeated Start
t
(RS-SU)
t
(RS-HD)
t
(SDA-F)
t
(SDA-R)
t
(P-SU)
Stop
t
(SP)
TIMING CHARACTERISTICS
PARAMETER CONDITIONS MIN MAX UNIT
SCL clock frequency
Standard 100
kHz
(SCL)
SCL clock frequency
Fast 400
kHz
Bus free time between stop and start conditions
Standard 4.7
µs
(BUF)
Bus free time between stop and start conditions
Fast 1.3
µ
s
Low period of the SCL clock
Standard 4.7
µs
(LOW)
Low period of the SCL clock
Fast 1.3
µ
s
High period of the SCL clock
Standard 4 µs
(HI)
High period of the SCL clock
Fast 600 ns
Setup time for (repeated) start condition
Standard 4.7 µs
(RS-SU
Setup time for (repeated) start condition
Fast 600 ns
t
(S-HD)
Hold time for (repeated) start condition
Standard 4 µs
t
(RS-HD)
Hold time for (repeated) start condition
Fast 600 ns
Data setup time
Standard 250
ns
(D-SU)
Data setup time
Fast 100
ns
Data hold time
Standard 0 900
ns
(D-HD)
Data hold time
Fast 0 900
ns
Rise time of SCL signal
Standard 20 + 0.1 C
B
1000
ns
(SCL-R)
Rise time of SCL signal
Fast 20 + 0.1 C
B
300
ns
Rise time of SCL signal after a repeated start condition and after an
Standard 20 + 0.1 C
B
1000
ns
(SCL-R1
Rise time of SCL signal after a repeated start condition and after an
acknowledge bit
Fast 20 + 0.1 C
B
300
ns
Fall time of SCL signal
Standard 20 + 0.1 C
B
1000
ns
(SCL-F)
Fall time of SCL signal
Fast 20 + 0.1 C
B
300
ns
Rise time of SDA signal
Standard 20 + 0.1 C
B
1000
ns
(SDA-R
Rise time of SDA signal
Fast 20 + 0.1 C
B
300
ns
Fall time of SDA signal
Standard 20 + 0.1 C
B
1000
ns
(SDA-F)
Fall time of SDA signal
Fast 20 + 0.1 C
B
300
ns
Setup time for stop condition
Standard 4 µs
(P-SU)
Setup time for stop condition
Fast 600 ns
C
(B)
Capacitive load for SDA and SCL lines 400 pF
t
(SP)
Pulse duration of suppressed spike Fast 50 ns
Noise margin at high level for each connected device (including hysteresis)
Standard
NH
Noise margin at high level for each connected device (including hysteresis)
Fast 0.2 V
DD
V