Datasheet
www.ti.com
ABSOLUTE MAXIMUM RATINGS
RECOMMENDED OPERATING CONDITIONS
PCM1772 , PCM1773
SLES010G – SEPTEMBER 2001 – REVISED MARCH 2007
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
over operating free-air temperature range unless otherwise noted
(1)
PCM1772
PCM1773
Supply voltage: V
CC1
, V
CC2
–0.3 V to 4 V
Supply voltage differences: V
CC1
, V
CC2
±0.1 V
Ground voltage differences ±0.1 V
Digital input voltage –0.3 V to 4 V
Input current (any terminals except supplies) ±10 mA
Operating temperature –40°C to 125°C
Storage temperature –55°C to 150°C
Junction temperature 150°C
Lead temperature (soldering) 260°C, 5 s
Package temperature (IR reflow, peak) 260°C
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
over operating free-air temperature range
MIN NOM MAX UNIT
Supply voltage: V
CC
1, V
CC
2 1.6 2.4 3.6 V
Digital input logic family CMOS
System clock 0.64 19.2 MHz
Digital input clock frequency
Sampling clock 5 50 kHz
Analog output load resistance 10 k Ω
Analog input level (V
CC
2 = 2.4 V) 1.4 Vp-p
Operating free-air temperature, T
A
–25 85 °C
2
Submit Documentation Feedback