Datasheet

www.ti.com
S/PDIF
Receiver
Evaluation Board
PCM1742
(1)
DEM−DAI1742
2nd−Order
Low−Pass
Filter
Notch FilterBand Limit
HPF = 22Hz
LPF = 22kHz
f
C
= 1kHz
f
3dB
= 54kHz or 108kHz
0% Full−Scale,
Dither Off (SNR)
60dBFS,
1kHz Sine Wave
(Dynamic Range)
S/PDIF
Output
A−Weight
Filter
(2)
rms Mode
Analyzer
and
Display
Digital
Generator
Idle-Channel Signal-to-Noise Ratio
PCM1742
SBAS176A DECEMBER 2000 REVISED APRIL 2005
KEY PERFORMANCE PARAMETERS AND MEASUREMENT (continued)
(1) Infinite-zero-detect mute disabled
(2) Results without A-weighting are approximately 3 dB worse.
Figure 36. Test Setup Dynamic Range and SNR Measurements
The SNR test provides a measure of the noise floor of the DAC. The input to the DAC is all-0s data, and the
DAC infinite-zero-detect mute function must be disabled (default condition at power up for the PCM1742). This
ensures that the delta-sigma modulator output is connected to the output amplifier circuit so that idle tones (if
present) can be observed and affect the SNR measurement. The dither function of the digital generator must
also be disabled to ensure an all-0s data stream at the input of the DAC. The measurement setup for SNR is
identical to that used for dynamic range, with the exception of the input signal level (see the notes provided in
Figure 36 ).