Datasheet
www.ti.com
PCM1738
SBAS174C – FEBRUARY 2002 – REVISED FEBRUARY 2007
DMF[1:0] Sampling Frequency Selection for the De-Emphasis Function
These bits are read/write.
Default value: 00
DMF[1:0] De-Emphasis Same Rate Selection
00 Disabled (default)
01 48 kHz
10 44.1 kHz
11 32 kHz
The DMF[1:0] bits are used to select the sampling frequency used for the digital de-emphasis
function when it is enabled by setting the DME bit. The de-emphasis curves are shown in the
Typical Performance Curves section of this data sheet.
For DSD mode, analog FIR filter performance may be selected using this register. Filter response
plots are shown in the Typical Performance Curves section of this data sheet. The register map is
shown in the Application for DSD Format (DSD Mode) Interface section of this data sheet.
DME Digital De-Emphasis Control
This bit is read/write.
Default value: 0
For DSD mode, DME must be set to 1.
DME = 0 De-emphasis disabled (default)
DME = 1 De-emphasis enabled
The DME bit is used to enable or disable the de-emphasis function for both channels.
MUTE Soft-Mute Control
This bit is read/write.
Default value: 0
MUTE = 0 MUTE disabled (default)
MUTE = 1 MUTE enabled
The MUTE bit is used to enable the soft-mute function for both channels. The mute function is also
available through the MUTE control input (pin 15). Soft mute is performed by using the 256-step
attenuator, cycling one step per time interval to – (mute). The time interval is set by the rate select
bit (ATS), located in register 19.
25
Submit Documentation Feedback