Datasheet

312
Table 35. Boundary Scan Terminal Order (Continued)
BOUNDARY SCAN
REGISTER NUMBER
PDV/PPM TERMINAL
NUMBER
GHK/ZHK
TERMINAL NUMBER
TERMINAL
NAME
GROUP DISABLE
REGISTER
BOUNDARY-SCAN
CELL TYPE
20 167 F12 S_C/BE1 19 Bidirectional
21 168 C13 S_PAR 19 Bidirectional
22 169 B13 S_SERR Input
23 171 E12 S_PERR 26 Bidirectional
24 172 C12 S_LOCK 26 Bidirectional
25 173 B12 S_STOP 26 Bidirectional
26 Control
27 175 A11 S_DEVSEL 26 Bidirectional
28 176 B11 S_TRDY 26 Bidirectional
29 177 C11 S_IRDY 26 Bidirectional
30 179 F11 S_FRAME 26 Bidirectional
31 180 A10 S_C/BE2 48 Bidirectional
32 182 E10 S_AD16 48 Bidirectional
33 183 F10 S_AD17 48 Bidirectional
34 185 C9 S_AD18 48 Bidirectional
35 186 F9 S_AD19 48 Bidirectional
36 188 A8 S_AD20 48 Bidirectional
37 189 B8 S_AD21 48 Bidirectional
38 191 F8 S_AD22 48 Bidirectional
39 192 E8 S_AD23 48 Bidirectional
40 194 B7 S_C/BE3 48 Bidirectional
41 195 C7 S_AD24 48 Bidirectional
42 197 A6 S_AD25 48 Bidirectional
43 198 B6 S_AD26 48 Bidirectional
44 200 C6 S_AD27 48 Bidirectional
45 201 A5 S_AD28 48 Bidirectional
46 203 B5 S_AD29 48 Bidirectional
47 204 E6 S_AD30 48 Bidirectional
48 Control
49 206 A4 S_AD31 48 Bidirectional
50 207 B4 S_REQ0 Input
51 2 E3 S_REQ1 Input
52 3 F5 S_REQ2 Input
53 4 G6 S_REQ3 Input
54 5 E2 S_REQ4 Input
55 6 E1 S_REQ5 Input
56 7 F3 S_REQ6 Input
57 8 F2 S_REQ7 Input
58 9 G5 S_REQ8 Input
59 10 F1 S_GNT0 61 Output
60 11 H6 S_GNT1 61 Output
61 Control