Datasheet

ABSOLUTE MAXIMUM RATINGS
(1)
RECOMMENDED OPERATING CONDITIONS
PCA9557
www.ti.com
.................................................................................................................................................... SCPS133I DECEMBER 2005 REVISED JUNE 2008
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
CC
Supply voltage range 0.5 6 V
V
I
Input voltage range
(2)
0.5 6 V
V
O
Output voltage range
(2)
0.5 6 V
I
IK
Input clamp current V
I
< 0 20 mA
I
OK
Output clamp current V
O
< 0 20 mA
I
IOK
Input/output clamp current V
O
< 0 or V
O
> V
CC
20 µ A
I
OL
Continuous output low current V
O
= 0 to V
CC
50 mA
I
OH
Continuous output high current V
O
= 0 to V
CC
50 mA
Continuous current through GND 250
I
CC
mA
Continuous current through V
CC
160
D package 73
DB package 82
DGV package 120
θ
JA
Package thermal impedance
(3)
° C/W
PW package 108
RGV package 51
RGY package 47
T
stg
Storage temperature range 65 150 ° C
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) The input negative-voltage and output voltage ratings may be exceeded if the input and output current ratings are observed.
(3) The package thermal impedance is calculated in accordance with JESD 51-7.
MIN MAX UNIT
V
CC
Supply voltage 2.3 5.5 V
SCL, SDA 0.7 × V
CC
5.5
V
IH
High-level input voltage V
A2 A0, P7 P0, RESET 2 5.5
SCL, SDA 0.5 0.3 × V
CC
V
IL
Low-level input voltage V
A2 A0, P7 P0, RESET 0.5 0.8
I
OH
High-level output current P7 P1 10 mA
I
OL
Low-level output current P7 P0 25 mA
T
A
Operating free-air temperature 40 85 ° C
Copyright © 2005 2008, Texas Instruments Incorporated Submit Documentation Feedback 11
Product Folder Link(s): PCA9557