Datasheet

P00
P01
P02
P03
P04
P05
A1
A0
A
B
P06
P07
P10
P11
P12
P13
P14
P15
P16
P17
V
CC
V
CC
V
CC
(5 V)
Controlled Switch
(e.g., CBT Device)
GND
INT
SDA
SCL
10 kW 10 kW 10 kW 10 kW
2 kW
INT
Subsystem 1
(e.g., Temperature
Sensor)
Subsystem 2
(e.g., Counter)
PCA9539
SDA
SCL
INT
GND
Keypad
ALARM
RESET
ENABLE
Subsystem 3
(e.g., Alarm)
Master
Controller
4
5
6
7
8
9
10
11
13
14
15
16
17
18
19
20
22
23
1
2
21
12
24
100 kW
100 kW 100 kW
RESET
3
V
CC
PCA9539
SCPS130F AUGUST 2005REVISED JANUARY 2011
www.ti.com
APPLICATION INFORMATION
Figure 15 shows an application in which the PCA9539 can be used.
A. Device address is configured as 1110100 for this example.
B. P00, P02, and P03 are configured as outputs.
C. P01 and P04 to P17 are configured as inputs.
D. Pin numbers shown are for DB, DBQ, DGV, DW, and PW packages.
Figure 15. Typical Application
22 Submit Documentation Feedback Copyright © 2005–2011, Texas Instruments Incorporated
Product Folder Link(s): PCA9539