Datasheet

ABSOLUTE MAXIMUM RATINGS
(1)
RECOMMENDED OPERATING CONDITIONS
PCA9536
www.ti.com
....................................................................................................................................................... SCPS125F APRIL 2006 REVISED AUGUST 2008
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
CC
Supply voltage range 0.5 6 V
V
I
Input voltage range
(2)
0.5 6 V
V
O
Output voltage range
(2)
0.5 6 V
I
IK
Input clamp current V
I
< 0 20 mA
I
OK
Output clamp current V
O
< 0 20 mA
I
IOK
Input/output clamp current V
O
< 0 or V
O
> V
CC
± 20 mA
I
OL
Continuous output low current V
O
= 0 to V
CC
50 mA
I
OH
Continuous output high current V
O
= 0 to V
CC
50 mA
Continuous current through GND 200
I
CC
mA
Continuous current through V
CC
160
D package 97
θ
JA
Package thermal impedance
(3)
DGK package 172 ° C/W
YZP package 102
T
stg
Storage temperature range 65 150 ° C
(1) Stresses beyond those listed under " absolute maximum ratings " may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under " recommended operating
conditions " is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) The input negative-voltage and output voltage ratings may be exceeded if the input and output current ratings are observed.
(3) The package thermal impedance is calculated in accordance with JESD 51-7.
MIN MAX UNIT
V
CC
Supply voltage 2.3 5.5 V
SCL, SDA 0.7 × V
CC
5.5
V
IH
High-level input voltage V
P3 P0 2 5.5
SCL, SDA 0.5 0.3 × V
CC
V
IL
Low-level input voltage V
P3 P0 0.5 0.8
I
OH
High-level output current P3 P0 10 mA
I
OL
Low-level output current P3 P0 25 mA
T
A
Operating free-air temperature 40 85 ° C
Copyright © 2006 2008, Texas Instruments Incorporated Submit Documentation Feedback 9
Product Folder Link(s): PCA9536