Datasheet
SDA
SCL
Start
ACK or Read Cycle
t
w
t
REC
RESET
0.3 y V
CC
V
CC
/2
t
RESET
Pn
R
L
= 1 kΩ
V
CC
C
L
= 50 pF
(see Note A)
SDA LOAD CONFIGURATION
DUT
SDA
P-PORT LOAD CONFIGURATION
V
CC
/2
t
RESET
DUT
C
L
= 50 pF
(see Note A)
Pn
2 × V
CC
500 W
500 W
PCA9535
SCPS129I – AUGUST 2005 – REVISED MAY 2008 ...........................................................................................................................................................
www.ti.com
PARAMETER MEASUREMENT INFORMATION (continued)
A. C
L
includes probe and jig capacitance.
B. All inputs are supplied by generators having the following characteristics: PRR ≤ 10 MHz, Z
O
= 50 Ω , t
r
/t
f
≤ 30 ns.
C. The outputs are measured one at a time, with one transition per measurement.
D. I/Os are configured as inputs.
E. All parameters and waveforms are not applicable to all devices.
Figure 14. Reset Load Circuits and Voltage Waveforms
20 Submit Documentation Feedback Copyright © 2005 – 2008, Texas Instruments Incorporated
Product Folder Link(s): PCA9535