Datasheet
www.ti.com
Absolute Maximum Ratings
(1)
Recommended Operating Conditions
P82B715
I
2
C BUS EXTENDER
SCPS145A – DECEMBER 2007 – REVISED FEBRUARY 2008
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
CC
Supply voltage range – 0.3 12 V
I
2
C bus voltage range Sx or Sy 0 V
CC
V
b
V
Buffered bus voltage range Lx or Ly 0 V
CC
Sx or Sy 60
I
O
Continuous output current mA
Lx or Ly 60
I
CC
Continuous current through V
CC
or GND 60 mA
D package 97
θ
JA
Package thermal impedance
(2)
° C/W
P package 85
T
stg
Storage temperature range – 55 125 ° C
T
A
Operating free-air temperature range – 40 85 ° C
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) The package thermal impedance is calculated in accordance with JESD 51-7.
MIN MAX UNIT
V
CC
Supply voltage
(1)
4.5 12 V
T
A
Operating free-air temperature – 40 85 ° C
(1) Operation with reduced performance is possible down to 3 V. Typical static sinking performance is not degraded at 3 V, but the dynamic
sink currents while the output is being driven through V
CC
/2 are reduced and can increase fall times. Timing-critical designs should
accommodate the specified minimums.
4 Submit Documentation Feedback Copyright © 2007 – 2008, Texas Instruments Incorporated
Product Folder Link(s): P82B715