Datasheet

OPA551, OPA552
7
SBOS100A
www.ti.com
TYPICAL PERFORMANCE CURVES (Cont.)
At T
J
= +25°C, V
S
= ±30V and R
L
= 3k, unless otherwise noted.
All temperatures are junction temperatures unless otherwise noted. Refer to the Applications Information section to calculate junction temperatures from ambient
temperatures for a specific configuration.
35
30
25
20
15
10
5
0
60 40 20 0 20 40 60 80 100 120 140
Junction Temperature (°C)
Slew Rate (V/µs)
SLEW RATE vs TEMPERATURE
OPA551
OPA552
30
25
20
15
10
5
0
5
30 20 10 0 10 20 30
Common-Mode Voltage (V)
Current (pA)
INPUT BIAS CURRENT AND INPUT OFFSET CURRENT
vs COMMON-MODE VOLTAGE
+I
B
I
B
I
OS
OFFSET VOLTAGE DRIFT
PRODUCTION DISTRIBUTION
Percent of Amplifiers (%)
Offset Drift µV/°C
< 0.0
< 1.5
< 3.0
< 4.50
< 6.0
< 7.5
< 9.0
< 10.5
< 12.0
< 13.5
< 15.0
18
16
14
12
10
8
6
4
2
0
Typical production
distribution of
packaged units.
100
10
1
1 10 100
Gain (V/V)
Settling Time (µs)
SETTLING TIME vs CLOSED-LOOP GAIN
OPA551
0.1%
OPA552
0.01%
OPA552
0.1%
OPA551
0.01%
7.6
7.2
6.8
6.4
6.0
405
395
385
375
365
0 5 10 15 20 25 30 35
Supply Voltage (V)
Quiescent Current (mA)
Short-Circuit Current (mA)
QUIESCENT CURRENT AND SHORT-CIRCUIT CURRENT
vs SUPPLY VOLTAGE
I
Q
+I
SC
I
SC