Datasheet
-75 0-50 -25 25 75 100 125
ExposedThermalPadTemperature( C)°
4.0
3.8
3.6
3.4
3.2
3.0
2.0
I
(mA)
Q
50
2.8
2.6
2.4
2.2
-75 0-50 -25 25 75 100 125
ExposedThermalPadTemperature( C)°
200
180
160
140
120
100
ShutdownCurrent( A)m
50
5TypicalUnitsShown
-75 -50 -25 0 25 50 75 100 125
ExposedThermalPadTemperature( C)°
100
10
1
0.1
I (pA)
B
-50 -40 -30 -20 -10 0 10 20 30 40 50
V (V)
CM
20
15
10
5
0
-5
-10
-15
-20
I (pA)
B
Common-ModeVoltageRange
-75 -50 -25 0 25 50 75 100 125
ExposedThermalPadTemperature( C)°
200
180
160
140
120
100
I (mA)
LIMIT
Sourcing
Sinking
-75 -50 -25 0 25 50 75 100 125
ExposedThermalPadTemperature( C)°
8
7
6
5
4
3
2
1
0
V toV-
FLAG
R =20k ,I =5mAW
P P
R =50kW
P P
,I =2mA
R =100kW
P P
,I =100 Am
R =200kW
P
,I =50 Am
P
OPA454
www.ti.com
....................................................................................................................................... SBOS391A – DECEMBER 2007 – REVISED DECEMBER 2008
TYPICAL CHARACTERISTICS (continued)
At T
P
= +25 ° C, V
S
= ± 50V, and R
L
= 4.8k Ω connected to GND, unless otherwise noted.
QUIESCENT CURRENT vs TEMPERATURE SHUTDOWN CURRENT vs TEMPERATURE
Figure 20. Figure 21.
INPUT BIAS CURRENT vs TEMPERATURE INPUT BIAS CURRENT vs COMMON-MODE VOLTAGE
Figure 22. Figure 23.
STATUS FLAG VOLTAGE vs TEMPERATURE
CURRENT LIMIT vs TEMPERATURE (E/D Com Connected to V – )
(1)
Figure 24. Figure 25.
(1) See Figure 57 in the Applications Information section.
Copyright © 2007 – 2008, Texas Instruments Incorporated Submit Documentation Feedback 9
Product Folder Link(s): OPA454