Datasheet
OPA356, 2356
2
SBOS212A
ABSOLUTE MAXIMUM RATINGS
(1)
Supply Voltage, V+ to V– ................................................................... 7.5V
Signal Input Terminals, Voltage
(2)
.................... (V–) – 0.5V to (V+) + 0.5V
Current
(2)
..................................................... 10mA
Output Short-Circuit
(3)
.............................................................. Continuous
Operating Temperature .................................................. –55°C to +150°C
Storage Temperature ...................................................... –65°C to +150°C
Junction Temperature .................................................................... +160°C
Lead Temperature (soldering, 10s) ............................................... +300°C
NOTE: (1) Stresses above these ratings may cause permanent damage.
Exposure to absolute maximum conditions for extended periods may degrade
device reliability. These are stress ratings only, and functional operation of the
device at these or any other conditions beyond those specified is not implied.
(2) Input terminals are diode-clamped to the power-supply rails. Input signals
that can swing more than 0.5V beyond the supply rails should be current limited
to 10mA or less. (3) Short-circuit to ground one amplifier per package.
ELECTROSTATIC
DISCHARGE SENSITIVITY
This integrated circuit can be damaged by ESD. Texas Instru-
ments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling
and installation procedures can cause damage.
ESD damage can range from subtle performance degradation
to complete device failure. Precision integrated circuits may be
more susceptible to damage because very small parametric
changes could cause the device not to meet its published
specifications.
PACKAGE/ORDERING INFORMATION
Top View
PIN CONFIGURATIONS
1
2
3
5
4
V+
–In
Out
V–
+In
OPA356
SOT23
1
2
3
4
8
7
6
5
NC
(1)
V+
Out
NC
(1)
NC
(1)
–In
+In
V–
OPA356
SO
1
2
3
4
8
7
6
5
V+
Out B
–In B
+In B
Out A
–In A
+In A
V–
OPA2356
MSOP, SO
A
B
NOTE: (1) NC means no internal connection.
SPECIFIED
PACKAGE TEMPERATURE PACKAGE ORDERING TRANSPORT
PRODUCT PACKAGE-LEAD DESIGNATOR
(1)
RANGE MARKING NUMBER
(2)
MEDIA, QUANTITY
OPA356AIDBV SOT23-5 DBV –40°C to +125°C OAAI OPA356AIDBVT Tape and Reel, 250
" """"OPA356AIDBVR Tape and Reel, 3000
OPA356AID SO-8 D –40°C to +125°C OPA356A OPA356AID Rails, 100
" """"OPA356AIDR Tape and Reel, 2500
OPA2356AIDGK MSOP-8 DGK –40°C to +125°C AYI OPA2356AIDGKT Tape and Reel, 250
" """"OPA2356AIDGKR Tape and Reel, 2500
OPA2356AID SO-8 D –40°C to +125°C OPA2356A OPA2356AID Rails, 100
" """"OPA2356AIDR Tape and Reel, 2500
NOTES: (1) For the most current specifications and package information, refer to our web site at www.ti.com. (2) Models labeled with “T” indicate smaller quantity
tape and reel, “R” indicates large quantity tape and reel and “D” indicates rails of specified quantity.