Datasheet

1
2
3
5
4
V+
–In+In
V–
Out
OPA354
DBV PACKAGE
(TOP VIEW)
OPA2354
DGK PACKAGE
(TOP VIEW)
1
2
3
4
8
7
6
5
+In A
–In A
Out A
V–
–In B
Out B
V+
+In B
OPA354-Q1
OPA2354-Q1
SBOS492A JUNE 2009REVISED AUGUST 2009.......................................................................................................................................................
www.ti.com
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.
ORDERING INFORMATION
(1)
T
A
PACKAGE
(2)
ORDERABLE PART NUMBER TOP-SIDE MARKING
SOT-23 – DBV Reel of 3000 OPA354AQDBVRQ1 OSFQ
–40°C to 125°C
MSOP – DGK Reel of 2500 OPA2354AQDGKRQ1 OSLQ
(1) For the most current package and ordering information, see the Package Option Addendum at the end of this document, or see the TI
web site at www.ti.com.
(2) Package drawings, thermal data, and symbolization are available at www.ti.com/packaging.
ABSOLUTE MAXIMUM RATINGS
(1)
over operating free-air temperature range (unless otherwise noted)
V
S
Supply voltage, V+ to V– 7.5 V
V
IN
Signal input terminals voltage (V– – 0.5 V) to (V+ + 0.5 V)
Output short-circuit duration Continuous
DBV package 150°C/W
θ
JA
Thermal impedance, junction to free air
DGK package 150°C/W
T
OP
Operating temperature –55°C to 150°C
T
STG
Storage temperature –65°C to 150°C
T
J
Junction temperature 150°C
T
LEAD
Lead temperature (soldering, 10 s) 300°C
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
MIN MAX UNIT
V
S
Supply voltage, V– to V+ 2.5 5.5 V
T
A
Operating free-air temperature –40 125 °C