Datasheet

OPA170
OPA2170
OPA4170
SBOS557B AUGUST 2011REVISED SEPTEMBER 2012
www.ti.com
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.
PACKAGE/ORDERING INFORMATION
(1)
PACKAGE PACKAGE TRANSPORT MEDIA,
PRODUCT PACKAGE-LEAD DESIGNATOR MARKING ORDERING NUMBER QUANTITY
OPA170AIDRLT Tape and Reel, 250
SOT553-5 DRL DAQ
OPA170AIDRLR Tape and Reel, 4000
OPA170AIDBVT Tape and Reel, 250
OPA170 SOT23-5 DBV OSVI
OPA170AIDBVR Tape and Reel, 3000
OPA170AID Rail, 75
SO-8 D O170A
OPA170AIDR Tape and Reel, 2500
OPA2170AIDGK Rail, 80
MSOP-8 DGK OPNI
OPA2170AIDGKR Tape and Reel, 2500
OPA2170AIDCUT Tape and Reel, 250
OPA2170 VSSOP-8 DCU OPQC
OPA2170AIDCUR Tape and Reel, 3000
OPA2170AID Rail, 75
SO-8 D 2170A
OPA2170AIDR Tape and Reel, 2500
OPA4170AID Rail, 50
SO-14 D OPA4170
OPA4170AIDR Tape and Reel, 2500
OPA4170
OPA4170AIPW Rail, 90
TSSOP-14 PW OPA4170
OPA4170AIPWR Tape and Reel, 2000
(1) For the most current package and ordering information, see the Package Option Addendum at the end of this document, or visit the
device product folder at www.ti.com.
ABSOLUTE MAXIMUM RATINGS
(1)
Over operating free-air temperature range, unless otherwise noted.
OPA170, OPA2170, OPA4170 UNIT
Supply voltage ±20, +40 (single supply) V
Voltage (V–) – 0.5 to (V+) + 0.5 V
Signal input terminals
Current ±10 mA
Output short circuit
(2)
Continuous
Operating temperature –55 to +150 °C
Storage temperature –65 to +150 °C
Junction temperature +150 °C
Human body model (HBM) 4 kV
ESD ratings
Charged device model (CDM) 750 V
(1) Stresses above these ratings may cause permanent damage. Exposure to absolute maximum conditions for extended periods may
degrade device reliability. These are stress ratings only, and functional operation of the device at these or any other conditions beyond
those specified is not implied.
(2) Short-circuit to ground, one amplifier per package.
2 Submit Documentation Feedback Copyright © 2011–2012, Texas Instruments Incorporated
Product Folder Links: OPA170 OPA2170 OPA4170