Absolute Maximum Ratings
over operating free-air temperature range (unless otherwise noted)
(1)
MIN MAX UNIT
V
CC+
(2)
22
Supply voltage V
V
CC–
(2)
–22
Differential input voltage
(3)
±30 V
V
I
Input voltage range (either input)
(4)
±22 V
Duration of output short circuit
(5)
Unlimited
D package 97
θ
JA
Package thermal impedance, junction to free air
(6)(7)
°C/W
P package 85
T
J
Operating virtual-junction temperature 150 °C
Lead temperature 1,6 mm (1/16 in) from case for 10 s 260 °C
T
stg
Storage temperature range –65 150 °C
(1) Stresses beyond those listed underAbsolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating
Conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values, unless otherwise noted, are with respect to the midpoint between V
CC+
and V
CC
.
(3) Differential voltages are at IN+ with respect to IN.
(4) The magnitude of the input voltage must never exceed the magnitude of the supply voltage or 15 V, whichever is less.
(5) The output may be shorted to ground or to either power supply.
(6) Maximum power dissipation is a function of T
J(max)
, θ
JA
, and T
A
. The maximum allowable power dissipation at any allowable ambient
temperature is P
D
= (T
J(max)
T
A
)/θ
JA
. Selecting the maximum of 150°C can affect reliability.
(7) The package thermal impedance is calculated in accordance with JESD 51-7.
Recommended Operating Conditions
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
CC±
Supply voltage ±3 ±18 V
V
IC
Common-mode input voltage V
CC±
= ±15 V –13 13 V
T
A
Operating free-air temperature 0 70 °C
Copyright © 1979–2014, Texas Instruments Incorporated Submit Documentation Feedback 3