Datasheet

NE555, NE555Y, SA555, SE555, SE555C
PRECISION TIMERS
SLFS022A – SEPTEMBER 1973 – REVISED SEPTEMBER 2000
5
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
operating characteristics, V
CC
= 5 V and 15 V
PARAMETER
TEST
CONDITIONS
SE555
NE555
SA555
SE555C
UNIT
MIN TYP MAX MIN TYP MAX
Initial error of timin
Each timer, monostable
§
T
A
=25
°
C
0.5% 1.5%* 1% 3%
interval
Each timer, astable
T
A
=
25°C
1.5% 2.25%
Temperature coefficient
Each timer, monostable
§
T
A
= MIN to MAX
30 100* 50
pp
m/
°
C
of timing interval
Each timer, astable
T
A
=
MIN
to
MAX
90 150
ppm/°C
Supply-voltage sensitivity
Each timer, monostable
§
T
A
=25
°
C
0.05 0.2* 0.1 0.5
%/V
of timing interval
Each timer, astable
T
A
=
25°C
0.15 0.3
%/V
Output-pulse rise time
C
L
= 15 pF,
100 200* 100 300
ns
Output-pulse fall time
L
T
A
= 25°C
100 200* 100 300
ns
* On products compliant to MIL-PRF-38535, this parameter is not production tested.
For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
Timing interval error is defined as the difference between the measured value and the average value of a random sample from each process
run.
§
Values specified are for a device in a monostable circuit similar to Figure 9, with the following component values: R
A
= 2 kto 100 k,
C = 0.1 µF.
Values specified are for a device in an astable circuit similar to Figure 12, with the following component values: R
A
= 1 kto 100 k,
C = 0.1 µF.