Datasheet

www.ti.com
Operating Characteristics
NA555 , NE555 , SA555 , SE555
PRECISION TIMERS
SLFS022F SEPTEMBER 1973 REVISED JUNE 2006
V
CC
= 5 V to 15 V, T
A
= 25 ° C (unless otherwise noted)
NA555
SE555 NE555
TEST
PARAMETER UNIT
SA555
CONDITIONS
(1)
MIN TYP MAX MIN TYP MAX
Each timer, monostable
(3)
T
A
= 25 ° C 0.5 1.5
(4)
1 3
Initial error of timing
%
interval
(2)
Each timer, astable
(5)
1.5 2.25
Each timer, monostable
(3)
T
A
= MIN to MAX 30 100
(4)
50
Temperature coefficient of ppm/
timing interval ° C
Each timer, astable
(5)
90 150
Each timer, monostable
(3)
T
A
= 25 ° C 0.05 0.2
(4)
0.1 0.5
Supply-voltage sensitivity of
%/V
timing interval
Each timer, astable
(5)
0.15 0.3
C
L
= 15 pF,
Output-pulse rise time 100 200
(4)
100 300 ns
T
A
= 25 ° C
C
L
= 15 pF,
Output-pulse fall time 100 200
(4)
100 300 ns
T
A
= 25 ° C
(1) For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
(2) Timing interval error is defined as the difference between the measured value and the average value of a random sample from each
process run.
(3) Values specified are for a device in a monostable circuit similar to Figure 9 , with the following component values: R
A
= 2 k to 100 k ,
C = 0.1 µ F.
(4) On products compliant to MIL-PRF-38535, this parameter is not production tested.
(5) Values specified are for a device in an astable circuit similar to Figure 12 , with the following component values: R
A
= 1 k to 100 k ,
C = 0.1 µ F.
6
Submit Documentation Feedback