Datasheet

CC
CC
Voltage @ 0.5 V node
V
CC
CC
Voltage @ 0.25 V node
V
MSP430G2x11
MSP430G2x01
www.ti.com
SLAS695I FEBRUARY 2010REVISED FEBRUARY 2013
Comparator_A+ (MSP430G2x11 only)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS V
CC
MIN TYP MAX UNIT
I
(DD)
CAON = 1, CARSEL = 0, CAREF = 0 3 V 45 µA
CAON = 1, CARSEL = 0, CAREF = 1, 2,
I
(Refladder/RefDiode)
or 3, 3 V 45 µA
No load at CA0 and CA1
V
(IC)
Common-mode input voltage CAON = 1 3 V 0 V
CC
-1 V
PCA0 = 1, CARSEL = 1, CAREF = 1,
V
(Ref025)
3 V 0.24
No load at CA0 and CA1
PCA0 = 1, CARSEL = 1, CAREF = 2,
V
(Ref050)
3 V 0.48
No load at CA0 and CA1
PCA0 = 1, CARSEL = 1, CAREF = 3,
V
(RefVT)
See Figure 14 and Figure 15 3 V 490 mV
No load at CA0 and CA1, TA = 85°C
V
(offset)
Offset voltage
(1)
3 V ±10 mV
V
hys
Input hysteresis CAON = 1 3 V 0.7 mV
T
A
= 25°C, Overdrive 10 mV,
120 ns
Without filter: CAF = 0
Response time
t
(response)
3 V
(low-high and high-low)
T
A
= 25°C, Overdrive 10 mV,
1.5 µs
With filter: CAF = 1
(1) The input offset voltage can be cancelled by using the CAEX bit to invert the Comparator_A+ inputs on successive measurements. The
two successive measurements are then summed together.
Copyright © 2010–2013, Texas Instruments Incorporated Submit Documentation Feedback 25