Datasheet

P6IN.6
Module X IN
Pad Logic
EN
D
P6OUT.6
P6DIR.6
P6SEL.6
DVss
0
1
0
1
Bus Keeper
To Scan I/F comparator input mux
From Scan I/F DAC
0: Input
1: Output
P6.6/SIFCI2/DACOUT
1
P6SEL.x must be set if the corresponding pins are used by the Scan IF.
MSP430FW42x
SLAS383D OCTOBER 2003REVISED JANUARY 2011
www.ti.com
Port P6, P6.6 Input/Output With Schmitt Trigger
NOTE
Analog signals applied to digital gates can cause current flow from the positive to the
negative terminal. The throughput current flows if the analog signal is in the range of
transitions 01 or 10. The value of the throughput current depends on the driving
capability of the gate. For MSP430, it is approximately 100 µA.
Use P6SEL.x=1 to prevent throughput current. P6SEL.x should be set, if an analog signal
is applied to the pin.
P6SEL.6 P6DIR.6 Port Function
0 0 P6.6 Input
0 1 P6.6 Output
1 0 SIFCI2 (Scan IF channel 2 comparator input)
1 1 SIFDAOUT (Scan IF DAC output)
50 Submit Documentation Feedback Copyright © 2003–2011, Texas Instruments Incorporated