Datasheet

MSP430FE42x2
MIXED SIGNAL MICROCONTROLLER
SLAS616 − JULY 2008
26
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature (unless otherwise
noted) (continued)
DCO
PARAMETER TEST CONDITIONS V
CC
MIN TYP MAX UNIT
f
(DCOCLK)
N
(DCO)
= 01Eh, FN_8 = FN_4 = FN_3 = FN_2 = 0, D = 2,
DCOPLUS= 0, f
Crystal
= 32.768 kHz
3 V 1 MHz
f
(DCO=2)
FN_8 = FN_4 = FN_3 = FN_2 = 0, DCOPLUS = 1 3 V 0.3 0.7 1.3 MHz
f
(DCO=27)
FN_8 = FN_4 = FN_3 = FN_2 = 0, DCOPLUS = 1 3 V 2.7 6.1 11.3 MHz
f
(DCO=2)
FN_8 = FN_4 = FN_3 = 0, FN_2 = 1, DCOPLUS = 1 3 V 0.8 1.5 2.5 MHz
f
(DCO=27)
FN_8 = FN_4 = FN_3 = 0, FN_2 = 1, DCOPLUS = 1 3 V 6.5 12.1 20 MHz
f
(DCO=2)
FN_8 = FN_4 = 0, FN_3 = 1, FN_2 = x, DCOPLUS = 1 3 V 1.3 2.2 3.5 MHz
f
(DCO=27)
FN_8 = FN_4 = 0, FN_3 = 1, FN_2 = x, DCOPLUS = 1 3 V 10.3 17.9 28.5 MHz
f
(DCO=2)
FN_8 = 0, FN_4 = 1, FN_3 = FN_2 = x, DCOPLUS = 1 3 V 2.1 3.4 5.2 MHz
f
(DCO=27)
FN_8 = 0, FN_4 = 1, FN_3 = FN_2 = x, DCOPLUS = 1 3 V 16 26.6 41 MHz
f
(DCO=2)
FN_8 = 1, FN_4 = FN_3 = FN_2 = x, DCOPLUS = 1 3 V 4.2 6.3 9.2 MHz
f
(DCO=27)
FN_8 = 1,FN_4 = FN_3 = FN_2 = x, DCOPLUS = 1 3 V 30 46 70 MHz
S
Step size between adjacent DCO taps:
1 < TAP 20 1.06 1.11
S
n
Step
size
between
adjacent
DCO
taps:
S
n
= f
DCO(Tap
n+1)
/ f
DCO(Tap
n)
, (see Figure 12 for taps 21 to 27)
TAP = 27 1.07 1.17
D
t
Temperature drift, N
(DCO)
= 01Eh, FN_8 = FN_4 = FN_3 = FN_2 = 0,
D = 2, DCOPLUS = 0
3 V –0.2 –0.3 –0.4 %/_C
D
V
Drift with V
CC
variation, N
(DCO)
= 01Eh,
FN_8 = FN_4 = FN_3 = FN_2 = 0, D = 2, DCOPLUS = 0
0 5 15 %/V
T
A
°CV
CC
− V
f
(DCO)
f
(DCO20
5
C)
f
(DCO)
f
(DCO3V)
1.8 3.02.4 3.6
1.0
20 6040 85
1.0
0−20−400
Figure 11. DCO Frequency vs Supply Voltage V
CC
and vs Ambient Temperature