Datasheet

MSP430F5638, MSP430F5637, MSP430F5636
MSP430F5635, MSP430F5634, MSP430F5633
MSP430F5632, MSP430F5631, MSP430F5630
www.ti.com
SLAS650D JUNE 2010REVISED AUGUST 2013
Low-Power Mode Supply Currents (Into V
CC
) Excluding External Current (continued)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
(1)(2)
-40°C 25°C 60°C 85°C
PARAMETER V
CC
PMMCOREVx UNIT
TYP MAX TYP MAX TYP MAX TYP MAX
Low-power mode 4.5
I
LPM4.5
3 V 0.2 0.3 0.6 0.7 0.9 1.4 µA
(LPM4.5)
(12)
(12) Internal regulator disabled. No data retention.
CPUOFF = 1, SCG0 = 1, SCG1 = 1, OSCOFF = 1, PMMREGOFF = 1 (LPM4.5); f
DCO
= f
ACLK
= f
MCLK
= f
SMCLK
= 0 MHz
Schmitt-Trigger Inputs General Purpose I/O
(1)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS V
CC
MIN TYP MAX UNIT
1.8 V 0.80 1.40
V
IT+
Positive-going input threshold voltage V
3 V 1.50 2.10
1.8 V 0.45 1.00
V
IT–
Negative-going input threshold voltage V
3 V 0.75 1.65
1.8 V 0.3 0.8
V
hys
Input voltage hysteresis (V
IT+
V
IT–
) V
3 V 0.4 1.0
For pullup: V
IN
= V
SS
R
Pull
Pullup or pulldown resistor 20 35 50 k
For pulldown: V
IN
= V
CC
C
I
Input capacitance V
IN
= V
SS
or V
CC
5 pF
(1) Same parametrics apply to clock input pin when crystal bypass mode is used on XT1 (XIN) or XT2 (XT2IN).
Inputs Ports P1, P2, P3, and P4
(1)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS V
CC
MIN MAX UNIT
Port P1, P2, P3, P4: P1.x to P4.x,
t
(int)
External interrupt timing
(2)
2.2 V, 3 V 20 ns
External trigger pulse duration to set interrupt flag
(1) Some devices may contain additional ports with interrupts. See the block diagram and terminal function descriptions.
(2) An external signal sets the interrupt flag every time the minimum interrupt pulse duration t
(int)
is met. It may be set by trigger signals
shorter than t
(int)
.
Leakage Current General Purpose I/O
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS V
CC
MIN MAX UNIT
I
lkg(Px.x)
High-impedance leakage current
(1)(2)
1.8 V, 3 V ±50 nA
(1) The leakage current is measured with V
SS
or V
CC
applied to the corresponding pin(s), unless otherwise noted.
(2) The leakage of the digital port pins is measured individually. The port pin is selected for input and the pullup or pulldown resistor is
disabled.
Outputs General Purpose I/O (Full Drive Strength)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS V
CC
MIN MAX UNIT
I
(OHmax)
= 3 mA
(1)
V
CC
0.25 V
CC
1.8 V
I
(OHmax)
= 10 mA
(2)
V
CC
0.60 V
CC
V
OH
High-level output voltage V
I
(OHmax)
= 5 mA
(1)
V
CC
0.25 V
CC
3 V
I
(OHmax)
= 15 mA
(2)
V
CC
0.60 V
CC
(1) The maximum total current, I
(OHmax)
and I
(OLmax)
, for all outputs combined should not exceed ±48 mA to hold the maximum voltage drop
specified.
(2) The maximum total current, I
(OHmax)
and I
(OLmax)
, for all outputs combined should not exceed ±100 mA to hold the maximum voltage
drop specified.
Copyright © 2010–2013, Texas Instruments Incorporated Submit Documentation Feedback 49
Product Folder Links: MSP430F5638 MSP430F5637 MSP430F5636 MSP430F5635 MSP430F5634 MSP430F5633
MSP430F5632 MSP430F5631 MSP430F5630